SLLSFE8B November 2024 – November 2025 TCAN2845-Q1 , TCAN2847-Q1
PRODUCTION DATA
The brownout behavior of the device depends upon VCC1 and whether VSUP drops below VSUP(PU)F. For devices where VCC1 = 5V, the device behaves as per Figure 10-8. When VSUP continues to fall to below VSUP(PU)F, the device behaves as a power on reset as per Figure 10-9. UVSUP5F is used for turning off VEXCC and UVSUP5R is used to turn on VEXCC is programmed to be on.
When VCC1 = 3.3V, Both UVSUP5R/F and UVSUP33R/F are used. The device behaves as per Figure 10-10 when VSUP drops below UVSUP33F but stays above VSUP(PU)F. When VSUP continues to fall to below VSUP(PU)F, the device behaves as a power on reset as per Figure 10-11.