SWRU626 December 2025 CC3501E , CC3551E
A channel can be armed in Capture mode by setting the SYSTIM.CHnCFG[0] MODE bit to 1.
In capture mode the channel captures the 32 bits of SYSTIM time based on the event which the channel receives. The resolution of these 32 bits is based on the type of channel which is being used. The capture can be configured on different edges of the input event . For more details refer to the SYSTIM.CHnCFG register.
By default a channel is disarmed after capture happens. The SYSTIM.CHnCFG[0] MODE bit is cleared to 0.