over recommended operating conditions (unless otherwise
noted)
| PARAMETER |
TEST
CONDITIONS |
MIN |
TYP |
MAX |
UNIT |
| VIL |
Input
Low Voltage |
|
|
0.35 × VDD(1) |
V |
| VILSS |
Input
Low Voltage Steady State |
|
|
0.35 × VDD(1) |
V |
| VIH |
Input
High Voltage |
0.65 × VDD(1) |
|
|
V |
| VIHSS |
Input
High Voltage Steady State |
0.65 × VDD(1) |
|
|
V |
| VHYS |
Input
Hysteresis Voltage |
150 |
|
|
mV |
| IIN(2) |
Input
Leakage Current. |
VI =
1.8V or VI =
0.0V |
|
|
±10 |
µA |
| RPU |
Pull-up Resistor |
10 |
20 |
30 |
kΩ |
| RPD |
Pull-down Resistor |
10 |
20 |
30 |
kΩ |
| VOL |
Output Low Voltage |
|
|
0.45 |
V |
| VOH |
Output High Voltage |
VDD(1) - 0.45 |
|
|
V |
| IOL(3) |
Low
Level Output Current |
VOL(MAX) |
8 |
|
|
mA |
| IOH(3) |
High
Level Output Current |
VOH(MIN) |
8 |
|
|
mA |
| SRI(5) |
Input
Slew Rate |
9f(4) or 1.08E+5 |
|
|
V/s |
(1) VDD stands for corresponding power supply. For more information on the
power supply name and the corresponding ball(s), see POWER column of the Pin
Attributes table.
(2) This parameter defines leakage current when the terminal is operating as an input,
undriven output, or both input and undriven output, without internal pulls enabled.
(3) The IOL and IOH
parameters define the minimum Low Level Output Current and High Level Output Current for
which the device is able to maintain the specified VOL and VOH
values. Values defined by these parameters should be considered the maximum current
available to a system implementation which needs to maintain the specified VOL
and VOH values for attached components.
(4) f = toggle frequency of the input signal in Hz.
(5) This MIN parameter only applies to input signal functions which are not defined in their
respective Timing and Switching Characteristics sections. Select the MIN parameter
which results in the largest value.