SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Global Status Register.
Return to Summary Table
| Instance Name | Physical Address |
|---|---|
| R5SS0 | 5350 0014h |
| R5SS1 | 5351 0014h |
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
| NU4 | |||||||
| R | |||||||
| 0h | |||||||
| 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| NU4 | |||||||
| R | |||||||
| 0h | |||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| NU4 | ST_ACTIVE | ||||||
| R | R | ||||||
| 0h | 5h | ||||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| NU5 | TEST_FAIL | TEST_DONE | |||||
| R | R | R | |||||
| 0h | 0h | 0h | |||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 31:12 | NU4 | R | 0h | Reserved bits |
| 11:8 | ST_ACTIVE | R | 5h | Indicates whether self test is currently active or not. 1010 = Self test is active Others = SelfTest is not active Once the self-test completes and ST_ENA_B4 key is cleared, this field will reflect the inactive value. |
| 7:2 | NU5 | R | 0h | Reserved bits |
| 1 | TEST_FAIL | R | 0h | Test_fail flag [RCP - Read, Clear on Writing in Priviledge Mode] 0 = Self test run has not failed 1 = SelfTest run has failed. Write Clear. |
| 0 | TEST_DONE | R | 0h | Test_done_flag [RCP - Read, Clear on Writing in Priviledge Mode] 0 = Not completed 1 = SelfTest run Completed |