SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Capture Interrupt Flag Register.
Return to Summary Table
| Instance Name | Physical Address |
|---|---|
| ECAP0 | 5024 002Eh |
| ECAP1 | 5024 102Eh |
| ECAP2 | 5024 202Eh |
| ECAP3 | 5024 302Eh |
| ECAP4 | 5024 402Eh |
| ECAP5 | 5024 502Eh |
| ECAP6 | 5024 602Eh |
| ECAP7 | 5024 702Eh |
| ECAP8 | 5024 802Eh |
| ECAP9 | 5024 902Eh |
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| RESERVED_1 | MUNIT_2_ERROR_EVT2 | MUNIT_2_ERROR_EVT1 | MUNIT_1_ERROR_EVT2 | MUNIT_1_ERROR_EVT1 | HRERROR | ||
| R | R | R | R | R | R | ||
| 0h | 0h | 0h | 0h | 0h | 0h | ||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CTR_CMP | CTR_PRD | CTROVF | CEVT4 | CEVT3 | CEVT2 | CEVT1 | INT |
| R | R | R | R | R | R | R | R |
| 0h | 0h | 0h | 0h | 0h | 0h | 0h | 0h |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15:13 | RESERVED_1 | R | 0h | Reserved |
| 12 | MUNIT_2_ERROR_EVT2 | R | 0h | Error event 2 Interrupt Flag from monitoring unit 2 |
| 11 | MUNIT_2_ERROR_EVT1 | R | 0h | Error event 2 Interrupt Flag from monitoring unit 2 |
| 10 | MUNIT_1_ERROR_EVT2 | R | 0h | Error event 2 Interrupt Flag from monitoring unit 1 |
| 9 | MUNIT_1_ERROR_EVT1 | R | 0h | Error event 2 Interrupt Flag from monitoring unit 1 |
| 8 | HRERROR | R | 0h | High resolution error status flag 1 Indicates the High resolution Error
occurred
0 Indicates no event occurred |
| 7 | CTR_CMP | R | 0h | Compare Equal Compare Status Flag. This flag is active only in APWM mode. 1 Indicates the counter (TSCTR) reached the
compare register value (ACMP)
0 Indicates no event occurred |
| 6 | CTR_PRD | R | 0h | Counter Equal Period Status Flag. This flag is only active in APWM mode. 1 Indicates the counter (TSCTR) reached the
period register value (APRD) and was reset.
0 Indicates no event occurred |
| 5 | CTROVF | R | 0h | Counter Overflow Status Flag. This flag is active in CAP and APWM mode. 1 Indicates the counter (TSCTR) has made the
transition from FFFFFFFF to 00000000
0 Indicates no event occurred |
| 4 | CEVT4 | R | 0h | Capture Event 4 Status Flag This flag is only active in CAP mode. 1 Indicates the fourth event occurred at
ECAPx pin
0 Indicates no event occurred |
| 3 | CEVT3 | R | 0h | Capture Event 3 Status Flag. This flag is active only in CAP mode. 1 Indicates the third event occurred at ECAPx
pin.
0 Indicates no event occurred |
| 2 | CEVT2 | R | 0h | Capture Event 2 Status Flag. This flag is only active in CAP mode. 1 Indicates the second event occurred at
ECAPx pin.
0 Indicates no event occurred |
| 1 | CEVT1 | R | 0h | Capture Event 1 Status Flag. This flag is only active in CAP mode. 1 Indicates the first event occurred at ECAPx
pin.
0 Indicates no event occurred |
| 0 | INT | R | 0h | Global Interrupt Status Flag 1 Indicates that an interrupt was generated. 0 Indicates no event occurred |