SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
SD Master Filter Enable.
Return to Summary Table
| Instance Name | Physical Address |
|---|---|
| SDFM0 | 5026 800Ch |
| SDFM1 | 5026 900Ch |
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| RESERVED_7 | RESERVED_6 | MFE | RESERVED_5 | RESERVED_4 | RESERVED_3 | ||
| R | R | R/W | R | R | R | ||
| 0h | 0h | 0h | 0h | 0h | 0h | ||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED_3 | RESERVED_2 | RESERVED_1 | |||||
| R | R | R | |||||
| 0h | 0h | 0h | |||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15:13 | RESERVED_7 | R | 0h | Reserved |
| 12 | RESERVED_6 | R | 0h | Reserved |
| 11 | MFE | R/W | 0h | Master Filter Enable 0:All the four data filter units of SDFM module are disabled. All FIFOs are cleared 1:Data filter units can be enabled if bit FEN is '1'. |
| 10 | RESERVED_5 | R | 0h | Reserved |
| 9 | RESERVED_4 | R | 0h | Reserved |
| 8:7 | RESERVED_3 | R | 0h | Reserved |
| 6:4 | RESERVED_2 | R | 0h | Reserved |
| 3:0 | RESERVED_1 | R | 0h | Reserved |