LMK3H0102EVM
LMK3H0102 評估模組
LMK3H0102EVM
概覽
LMK3H0102 評估模組提供完整的計時平台,可評估具整合式 BAW (突破性體聲波) 型振盪器的 LMK3H0102 時鐘產生器的時鐘性能、針腳配置、軟體配置和功能。
特點
- 業界首款 BAW 型無參考時鐘產生器
- 僅可透過 USB 供電,可選擇外部電源
- 透過 TICS Pro GUI 提供軟體支援,可用於產生配置
時鐘產生器
訂購並開始開發
開發板
LMK3H0102EVM — LMK3H0102 evaluation module
LMK3H0102EVM — LMK3H0102 evaluation module
支援軟體
TICSPRO-SW — TICS Pro GUI and Live Programming Tool for Clocking Devices
支援產品和硬體
產品
RF PLL 與合成器
振盪器
時脈網路同步器
時鐘抖動清除器
時鐘產生器
時鐘緩衝器
硬體開發
開發板
TICSPRO-SW — TICS Pro GUI and Live Programming Tool for Clocking Devices
TICS Pro 1.7.7.6 installer binary for Windows operating system
產品
RF PLL 與合成器
振盪器
時脈網路同步器
時鐘抖動清除器
時鐘產生器
時鐘緩衝器
硬體開發
開發板
文件
TICS Pro 1.7.7.6 Software Manifest
TICS Pro 1.7.7.6 Release Notes
版本資訊
Added Features
LMK5Bxxyyy, LMK5Cxxyyy
- Warnings and errors improved, particularly corrective suggestions
- REFx_FREQ=0 automatically disables DPLL reference input selection for that input
- Input validation enabled and disabled by start page settings, including 1PPS
- APLL reference selection moved to Step 5, just before clock output definition
- Quick-set multiple outputs to the same settings on frequency planner
- BAW VCO allows some ppm deviation
- Force SYSREF option on OUT0/1
- Expose DPLLx_LCK_TIMER field
- Match LMK05318B EEPROM page design
- .EPR export option
- EEPROM SRAM programming generation support
- For complete changelist, see release notes
LMK3H0102
- Configuration search tool
- Wizard: voltage selection option
Bug Fixes
- LMK04832-SP, LMK04832-SEP, LMK04714-Q1, LMK04368-EP - PD_FIN0 corrected to FIN0_PD
- LMK3H0102 - Several wizard bugfixes
Known Issues
- LMK5C33216 - When cascading from VCO3 to DPLL input, the divide value must manually be entered into DPLLx_REF5_RDIV as ( VCO3 output frequency / DPLLx TDC frequency )
- LMK05318 - In some cases, it is necessary to press "Calculate Frequency Plan" twice for correct VCO2 frequency. This issue is resolved in LMK05318B GUI.
- Burst mode page looping requires long delays to halt, and halting may crash the GUI. If possible, do not loop in burst mode.
- User Controls page can sometimes become desynchronized from Raw Registers and other pages. Refer to Raw Registers or other pages for correct values. Saving/Loading and Import/Export of register data is unaffected, and register data will still be written to and read from connected devices correctly.
技術文件
=
TI 所選的重要文件
找不到結果。請清除您的搜尋條件,然後再試一次。
檢視所有 2
| 重要文件 | 類型 | 標題 | 格式選項 | 下載最新的英文版本 | 日期 | |
|---|---|---|---|---|---|---|
| * | EVM User's guide | LMK3H0102 Evaluation Module User's Guide | PDF | HTML | 2023/11/14 | ||
| 證書 | LMK3H0102EVM EU Declaration of Conformity (DoC) | PDF | HTML | 2023/11/8 |