TIDUA05B June 2015 – March 2025
To understand the requirements for an electrical interface module to Sin/Cos encoders, some example industrial Sin/Cos encoder models have been analyzed. The corresponding parameters are listed in Table 1-1.
| SIN/COS ENCODER MODEL | SUPPLY VOLTAGE | CURRENT CONSUMPTION |
|---|---|---|
| 1 | 5-V ± 0.5-V DC | < 120 mA |
| 2 | 5 V ± 10% | 150 mA |
| 3 | 5 V ± 5% | 70 mA (min) |
The power supply of the Sin/Cos encoder needs to be within this specification.
The analog signal chain need to be specified to at least meet the requirements listed in Table 1-2 with respect to signal amplitudes, offset, and maximum frequency.
| SIN/COS ENCODER MODEL | SIGNAL LEVEL A, B | DC OFFSET | LINE COUNT N | LIMIT FREQUENCY (–3 dB) |
|---|---|---|---|---|
| 1 | 0.6 to 1.2 VPP, 1 VPP typical | 2.5 V ±0.5 V | 50 to 5000 | ≥180 kHz |
| 2 | 1 VPP (+20%,-40%) | 2.5 V ±0.5 V | 120 kHz | |
| 3 | 1 VPP (±10%) | 2.5 V ±100 mV | 1024 or 2048 | 400 kHz |
| SIN/COS ENCODER MODEL | USABLE COMPONENT G AT REFERENCE MARK | QUIESCENT VALUE H OUTSIDE REFERENCE MARK | DC OFFSET |
|---|---|---|---|
| 1 | 0.5 VPP typical, 0.2 VPP min | –1.7 V | 2.5 V |
| SIN/COS ENCODER MODEL | SYSTEM ACCURACY | SHAFT MECHANICAL SPEED |
|---|---|---|
| 1 | 1/20 of grating period | < 16000 rpm |