SLYY234 December 2024 AMC0106M05 , AMC0106M25 , AMC0136 , AMC0311D , AMC0311S , AMC0386 , AMC0386-Q1 , AMC1100 , AMC1106M05 , AMC1200 , AMC1200-Q1 , AMC1202 , AMC1203 , AMC1204 , AMC1211-Q1 , AMC1300 , AMC1300B-Q1 , AMC1301 , AMC1301-Q1 , AMC1302-Q1 , AMC1303M2510 , AMC1304L25 , AMC1304M25 , AMC1305M25 , AMC1305M25-Q1 , AMC1306M05 , AMC1306M25 , AMC1311 , AMC1311-Q1 , AMC131M03 , AMC1336 , AMC1336-Q1 , AMC1350 , AMC1350-Q1 , AMC23C12 , AMC3301 , AMC3330 , AMC3330-Q1
Figure 2 shows the implementation of an isolated-modulator-based measurement design.
Figure 2 Isolated
Modulator ImplementationThe input stage of an isolated modulator is similar to that of an isolated amplifier. The drivers transfer the modulator output across the isolation barrier. The isolated data output DOUT provides a digital bit stream of 1's and 0's at a much higher frequency (up to 20 MHz). The time average of this bit stream output is proportional to the analog input voltage. The measured signal is reconstructed with a digital filter inside the microcontroller families such as the TMS320F2807x and TMS320F2837x, a DSP, or a field programmable gate array (FPGA).