SPRUIE9D May 2017 – May 2024 DRA74P , DRA75P , DRA76P , DRA77P
Table 3-282 lists the static dependency of the clock domain with respect to other clock domains of the device.
| Clock Domain Name | Default Setting | Control Bit Field | Access Type |
|---|---|---|---|
| CD_IVA | Disabled | CM_CAM_STATICDEP[2] IVA_STATDEP | Read/write |
| CD_L3_MAIN1 | Always enabled | CM_CAM_STATICDEP[5] L3MAIN1_STATDEP | Read only |
| CD_L4_CFG | Disabled | CM_CAM_STATICDEP[12] L4CFG_STATDEP | Read only |
| CD_EMIF | Always enabled | CM_CAM_STATICDEP[4] EMIF_STATDEP | Read/write |
| CD_EVE1 | Disabled | CM_CAM_STATICDEP[19] EVE1_STATDEP | Read/write |
| CD_EVE2 | Disabled | CM_CAM_STATICDEP[20] EVE2_STATDEP | Read/write |
| CD_GMAC | Disabled | CM_CAM_STATICDEP[25] GMAC_STATDEP | Read/write |
| CD_L4PER3 | Disabled | CM_CAM_STATICDEP[27] L4PER3_STATDEP | Read/write |
| CD_VPE | Disabled | CM_CAM_STATICDEP[28] VPE_STATDEP | Read/write |