SPRADO8 March 2025 AM62L
Using an external clock (LVCMOS) oscillator as the clock source for the processor and the EPHY allows for the use of either a shared oscillator or a separate oscillator. When using one oscillator, buffer the clock output before connecting to the processor and EPHY.
Use one output, individual buffer, or dual or multiple output buffer to connect the clock output of the oscillator to the processor and EPHYs.
For specific use case (requirement for some of the industrial applications using one Time Sensitive Networking (TSN)) input or two or more outputs (based on number of EPHYs used) buffer is recommended for the processor and the EPHYs.
Verify that the crystal XO of the EPHY is connected according to the recommended guidelines.