Once the M_CAN is initialized and CCCR.INIT is reset to zero, the M_CAN synchronizes to the CAN bus, and is ready for communication.
After passing the acceptance filtering, received messages including Message ID and DLC are stored in a dedicated Rx Buffer or into Rx FIFO 0 or Rx FIFO 1.
For messages to be transmitted, dedicated Tx Buffers and/or a Tx FIFO or a Tx Queue can be initialized or updated. Automated transmission on the reception of remote frames is not implemented.