SWCU195A December 2024 – May 2025 CC2744R7-Q1 , CC2745P10-Q1 , CC2745R10-Q1 , CC2745R7-Q1 , CC2755R10
When RXD pin goes low, counter is started to detect break condition.
If the break field duration is longer than 11-bittimes LINBRK will be set.
If the break field duration is longer than 21-bit times LINBTOE will be set.
If the break field duration is shorter than 11-bit times (minimum can be 150us as per LIN protocol) breakcondition is treated invalid and ignored.
This will be fine since the purpose of wake signal transmission is to wake up the device only and, in this case, device is already in active/idle state and UART is ready to receive break/synch fields.
If necessary DIO based interrupt on RXD pin can also be generated for software use.
RXD pin will not glitch as it is generated by the LIN transceiver.