SPRUJB6B November 2024 – May 2025 AM2612
Since the serial link characteristics are based on how the control registers are programmed, the PRU-ICSS UART0 module will expect the control registers to be static while it is busy engaging in a serial communication. Therefore, changing the control registers while the module is still busy communicating with another serial device will most likely cause an error condition and should be avoided.