Figure 25-25 shows the DTO event condition asserted when there is a read data time-out.
Figure 25-25 Read Data Time-Outt1 – Data time-out counter is loaded and starts after command transmission.
t2 – Data time-out counter stops and if it is 0, the MMCHS_STAT[20] DTO bit is generated.
t3 – Data time-out counter is loaded and starts after data block + CRC transmission.