SPRUHZ7K August 2015 – April 2024 AM5706 , AM5708 , AM5716 , AM5718 , AM5718-HIREL
There is no automatic gating control to ensure that internal weak pull-up or pull-down resistors on a pad are disconnected whenever pad is configured as output. If a pad is always configured in output mode, it is recommended for user software to disable any internal pull resistor tied to it to avoid unnecessary consumption.
Table 18-9 describes the software controls available for pad internal pull-up and pull-down resistors in the control module pad configuration registers.
| PULL | Pad Behavior | |
|---|---|---|
| PULLTYPESELECT | PULLUDENABLE | |
| 0 | 1 | Pull-down selected but not activated |
| 0 | 0 | Pull-down selected and activated |
| 1 | 1 | Pull-up selected but not activated |
| 1 | 0 | Pull-up selected and activated |