SPRUJC6A December 2024 – July 2025 AM2752-Q1 , AM2754-Q1
See reference [R1].
Return to Summary Table
| Instance Name | Physical Address |
|---|---|
| MLB0 | 02F8 2080h |
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
| RSV1 | |||||||
| R/W | |||||||
| 0h | |||||||
| 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| RSV1 | |||||||
| R/W | |||||||
| 0h | |||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| EN | RSV0 | ||||||
| R/W | R/W | ||||||
| 0h | 0h | ||||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RSV0 | RST1 | RST0 | |||||
| R/W | R/W | R/W | |||||
| 0h | 0h | 0h | |||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 31:16 | RSV1 | R/W | 0h | Reserved (write default value) Reset Source: prst_n |
| 15 | EN | R/W | 0h | HBI enable: 1 = enabled, 0 = disabled Reset Source: prst_n |
| 14:2 | RSV0 | R/W | 0h | Reserved (write default value) Reset Source: prst_n |
| 1 | RST1 | R/W | 0h | AGU1 software reset: 1 = reset active, 0 = reset inactive Reset Source: prst_n |
| 0 | RST0 | R/W | 0h | AGU0 software reset: 1 = reset active, 0 = reset inactive Reset Source: prst_n |