ADS1293

ACTIVE

24-bit, 3-ch, Low-Power Analog Front END (AFE) for ECG Applications

Top

Product details

Parameters

Resolution (Bits) 24 Number of input channels 3 Sample rate (Max) (kSPS) 25.6 Interface type SPI Architecture Delta-Sigma Input type Differential Multi-channel configuration Simultaneous Sampling Rating Catalog Reference mode Int Input range (Max) (V) 0.4 Input range (Min) (V) 0 Features Oscillator, PGA Operating temperature range (C) -20 to 85 Power consumption (Typ) (mW) 0.9 Analog voltage AVDD (Min) (V) 2.7 Analog voltage AVDD (Max) (V) 5.5 Digital supply (Min) (V) 1.65 Digital supply (Max) (V) 3.6 open-in-new Find other Precision ADCs (<=10MSPS)

Package | Pins | Size

WQFN (RSG) 28 25 mm² 5 x 5 open-in-new Find other Precision ADCs (<=10MSPS)

Features

  • Three High-Resolution Digital ECG Channels With
    Simultaneous Pace Output
  • EMI-Hardened Inputs
  • Low Power: 0.3 mW/channel
  • Input-Referred Noise: 7 µVpp (40-Hz Bandwidth)
  • Input Bias Current: 175 pA
  • Data Rate: Up to 25.6 ksps
  • Differential Input Voltage Range: ±400 mV
  • Analog Supply Voltage: 2.7 V to 5.5 V
  • Digital I/O Supply Voltage: 1.65 V to 3.6 V
  • Right-Leg Drive Amplifier
  • AC and DC Lead-Off Detection
  • Wilson and Goldberger Terminals
  • ALARMB Pin for Interrupt Driven Diagnostics
  • Battery Voltage Monitoring
  • Built-In Oscillator and Reference
  • Flexible Power-Down and Standby Modes
open-in-new Find other Precision ADCs (<=10MSPS)

Description

The ADS1293 incorporates all features commonly required in portable, low-power medical, sports, and fitness electrocardiogram (ECG) applications. With high levels of integration and exceptional performance, the ADS1293 enables the creation of scalable medical instrumentation systems at significantly reduced size, power, and overall cost.

The ADS1293 features three high-resolution channels capable of operating up to 25.6 ksps. Each channel can be independently programmed for a specific sample rate and bandwidth allowing users to optimize the configuration for performance and power. All input pins incorporate an EMI filter and can be routed to any channel through a flexible routing switch. Flexible routing also allows independent lead-off detection, right-leg drive, and Wilson/Goldberger reference terminal generation without the need to reconnect leads externally. A fourth channel allows external analog pace detection for applications that do not use digital pace detection.

The ADS1293 incorporates a self-diagnostics alarm system to detect when the system is out of the operating conditions range. Such events are reported to error flags. The overall status of the error flags is available as a signal on a dedicated ALARMB pin.

The device is packaged in a 5-mm × 5-mm × 0.8-mm, 28-pin LLP. Operating temperature ranges from –20°C to 85°C.

open-in-new Find other Precision ADCs (<=10MSPS)
Download

Technical documentation

= Top documentation for this product selected by TI
No results found. Please clear your search and try again. View all 7
Type Title Date
* Datasheet ADS1293 Low-Power, 3-Channel, 24-Bit Analog Front-End for Biopotential Measurements datasheet (Rev. C) Dec. 17, 2014
White papers Fundamentals of Precision ADC Noise Analysis Jun. 19, 2020
Application notes QFN and SON PCB Attachment (Rev. B) Aug. 24, 2018
Application notes Digital Filter Types in Delta-Sigma ADCs Jun. 27, 2017
White papers Best of Baker's Best: Precision Data Converters -- Delta-Sigma ADCs Mar. 19, 2015
Application notes MSP430 Interface to the ADS1293 Code Library May 17, 2013
User guides ADS1293EVM User's Guide (Rev. B) Jan. 23, 2013

Design & development

For additional terms or required resources, click any title below to view the detail page where available.

Hardware development

EVALUATION BOARDS Download
document-generic User guide
99
Description

The ADS1293EVM is a demonstration kit for the ADS1293, a three channel, 24-bit delta-sigma (ΔΣ) analog-to-digital converter (ADC), internal reference, and an on-board oscillator. The ADS1293 chip incorporates all of the features that are commonly required in medical electrocardiogram (...)

Features
  • Easy to use online and offline WEBENCH Medical AFE Designer tool
  • Clickable block diagram in tool
  • Pre-programmed 3-lead and 5-lead ECG application
  • Easy-to-use evaluation software for Microsoft™ Windows XP or Windows 7
  • Built-in analysis tools including oscilloscope and histogram displays, estimated device (...)

Software development

SUPPORT SOFTWARE Download
SNAC050.ZIP (31480 KB)
SUPPORT SOFTWARE Download
SNAC054.ZIP (73 KB)

Design tools & simulation

SIMULATION MODELS Download
SNAM124.ZIP (197 KB) - IBIS Model
SIMULATION TOOLS Download
PSpice® for TI design and simulation tool
PSPICE-FOR-TI — PSpice® for TI is a design and simulation environment that helps evaluate functionality of analog circuits. This full-featured, design and simulation suite uses an analog analysis engine from Cadence®. Available at no cost, PSpice for TI includes one of the largest model libraries in the (...)
Features
  • Leverages Cadence PSpice Technology
  • Preinstalled library with a suite of digital models to enable worst-case timing analysis
  • Dynamic updates ensure you have access to most current device models
  • Optimized for simulation speed without loss of accuracy
  • Supports simultaneous analysis of multiple products
  • (...)
SIMULATION TOOLS Download
SPICE-based analog simulation program
TINA-TI TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages (...)
document-generic User guide
CALCULATION TOOLS Download
Analog-to-digital converter (ADC) input driver design tool supporting multiple input types
ADC-INPUT-CALC ADC-INPUT-CALC is an online tool that provides support for designing the input buffer to an analog-to-digital converter (ADC). It offers 24 different op-amp based buffer circuits that can be used to drive an ADC input. The available topologies cover differential, single-ended and transformer-coupled (...)
CALCULATION TOOLS Download
Analog engineer's calculator
ANALOG-ENGINEER-CALC — The Analog Engineer’s Calculator is designed to speed up many of the repetitive calculations that analog circuit design engineers use on a regular basis. This PC-based tool provides a graphical interface with a list of various common calculations ranging from setting op-amp gain with feedback (...)
Features
  • Expedites circuit design with analog-to-digital converters (ADCs) and digital-to-analog converters (DACs)
    • Noise calculations
    • Common unit translation
  • Solves common amplifier circuit design problems
    • Gain selections using standard resistors
    • Filter configurations
    • Total noise for common amplifier configurations
  • (...)
BILL OF MATERIALS (BOM) Download
SNVC113.PDF (102 KB)
GERBER FILES Download
SNVC114.ZIP (901 KB)
SCHEMATICS Download
SNVC112.PDF (214 KB)

Reference designs

REFERENCE DESIGNS Download
Wireless Heart Monitor with Bluetooth Low Energy
TIDA-00096 The Wireless Heart Rate Monitor with Bluetooth low-energy (BLE) is intended as a reference design that customers can use to develop end-products for battery-powered, 3-channel health and fitness electrocardiogram (ECG) applications.  The ADS1293 is a highly integrated low-power analog front end (...)
document-generic Schematic document-generic User guide

CAD/CAE symbols

Package Pins Download
WQFN (RSG) 28 View options

Ordering & quality

Recommended products may have parameters, evaluation modules or reference designs related to this TI product.

Support & training

TI E2E™ forums with technical support from TI engineers

Content is provided "as is" by TI and community contributors and does not constitute TI specifications. See terms of use.

If you have questions about quality, packaging or ordering TI products, see TI support. ​​​​​​​​​​​​​​

Videos

Related videos